DA1174 IBS Duel Twin Battery Split Charge Relay & Digital Monitoring System

$189.71 (-40%)

99977

  • Brand: IBS Britpart
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Manufacturer Part Number: DA1174
  • Restocking Fee: No
  • Returns Accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Item must be returned within: 60 Days
  • DA1174 IBS Duel Twin Battery Split Charge Relay & Digital Monitoring System
    This product data sheet is originally written in English.
    Powered by
    Frooition
    All Items
    See our eBay store for more great items >>
    Shop Categories
    Wheel Nuts
    Hi lift jacks & Acc.
    Bow shackles
    Ropes and straps
    Winches & Acc.
    Tyres
    Safari Snorkes
    Defender Parts
    Discovery Parts
    Range Rover Parts
    Wheels
    Tools
    Gift Ideas
    Series
    Discovery 1 89-93
    Discovery 1 94-98
    Discovery 2 99-04
    Range Rover Classic
    Range Rover P38
    Range Rover l322
    Freelander
    Discovery 3
    Defender 90 & 110
    DA1174 IBS Duel Twin Battery Split Charge Relay & Digital Monitoring System
    Item Description
    IBS Split Charge System (branded by Britpart)
    Separates the starter battery from auxiliary battery if the vehicle has stopped and links them while the car is running.
    This fully automatic Swiss made by IBS (one of the best manufacturers) Microprocessor Controlled Dual Battery Management System separates the starter battery from auxiliary battery if the vehicle has stopped and links them while the car is running. All systems are equipped with a 200A power relay. For emergency situation all systems are equipped with the manual override function (link). This manual linking function (called load sharing) is very helpful for jump starting or when using high current appliances such as an electrical recovery winch, power inverter or compressor. The kit includes a 4.7m wiring loom with sealed automotive plug, battery and crimp terminals for easy installation.
    The battery monitor is installed in the vehicle (dash) and informs the driver about the charge level of both batteries, the charging voltage from the alternator or an additionally installed solar system and the relay link status. The system offers low battery alarm on both batteries and a link failure alarm. Includes a manual link for 30 and 120 minutes with automatic return.
    Functions
    Display of Battery Voltage (Energy Level)
    LED indicators:
    Green: Batteries are in the safe working range
    Yellow: Check batteries
    Red: Batteries should be charged
    The LED’s show the energy level if all loads are switched off:
    12.6V = 100%
    12.4V = 75%
    12.2V = 50%
    12.0V = 25%
    11.0V = flashing and beeping indicates low battery situation
    This function is called by pressing the display button for about 30 seconds.
    Display of Charge Voltage while charging
    LED indicators:
    Red: >14.5V: High loading of batteries, may be present at cold ambient temp. for a longer time.
    Yellow: >14.0V: Proper charge mode.
    Green: <14.0V: Save charge mode, no damage to batteries.
    Bi-directional Automatic Battery link
    While the engine is running the main and auxiliary batteries are linked together for parallel charging from the alternator (green LED linked is on). If the engine is stopped, the two batteries will be disconnected automatically with some delay. Appliances as fridges, lights, compressors, inverters are now safely fed from the auxiliary battery. With the additional charge by solar equipment, battery charger or generator is sufficient for charging, the starter battery will be charged automatically with auxiliary battery together (green LED “link” lights).
    Manual Battery “link”
    In an emergency situation (defective or empty main battery) or in case of higher power consumption the two batteries (main & auxiliary) may be connected together by activating the link button (red LED manually linked is on) After a laps of time of 30 minutes (or immediately after activating the auto button), the system returns to the automatic mode. When using an electric winch, the battery connection can be activated for 120 minutes by pressing twice the link button. In this mode sounds every 30 seconds a beep to remind this status (auto return after time expired). The load sharing function with the manual battery connection reduces the load on the alternator, the wiring and the batteries in the use of the winch.
    Alarm functions:
    Low battery alarm
    If the battery voltage of one or both of the batteries, is for a longer period below 12V, the sound low battery with “Beep” and the LED “Low Battery” of the corresponding battery (main and / or auxiliary) flashes. With the display button, the “Beep” is switched off. The blinking LED “Low Battery” is reset if the battery voltage is exceeding 12V.
    Link failure alarm
    The monitor monitors the charge on both batteries. When fitting charge (from alternator, solar, charger) no charge to the other battery is detected, the link error alarm with flashing green LED “linked” and the “Beep” sounds. If this error occurs, check immediately the wiring of the power cables to (relay, battery terminals, crimp contacts, control relays). After bug fixes, alarm will automatically reset.
    Deactivation of automatic and manual battery dual link function
    Is there a problem with the auxiliary battery (aux) as short circuit of cells, short circuit or defective battery housing, leading to damage of the generator (alternator). In an emergency situation the battery system can be operated in the vehicle in the basic configuration (alternator, starter battery without additional charge to auxiliary battery). By pressing the link button for 6 seconds (until the sound of the beep), the link is deactivated. In this mode, no manual and automatic battery connection is possible. This feature can after solving the battery problem of the auxiliary battery by pressing the auto button for 6 seconds to be reset. Now the system is working again with all the functions.
    Specifications
    Supply voltage: 4 – 16V
    System voltage: 12V
    Measuring range (sense wire blue): 8 – 16V
    Display range (battery voltage): 11.0V – 12.8V
    Alarm level main and aux: 12.0V
    Display range (charge): 13.0V – 14.5V
    Accuracy: +/-1%
    Consumption monitor: 1mA
    Consumption max. display active (30 sec): 20mA
    Isolator link-on/off threshold: 13.1V/13.0V
    Consumption on-state (relay): 0.6A
    Relay continuous load current: 200A
    Relay current inrush: 500A
    Relay contact material: Silver (AG SnO2)
    Free combination of batteries possible?: Yes
    Operating temperature: -40°C – +80°C
    Housing: ABS black
    Sealing level: IP40
    Size, dimensions: 100 x 65 x 24mm
    Weight: 800g
    Cabling:
    Red – Supply/sense (main battery)
    Black – GND (main battery)
    Blue – Sense (aux battery)
    Green – Control relay (open collector)
    Protected against:
    Against wrong polarity
    Against overload of solenoid driving circuit on PC board with SMD electronically security devices, no fuses have to be replaced
    About Us
    About Us
    Payment
    Terms
    Returns
    About Us
    We’re a family run UK based company offering quality items at prices far cheaper than the high street. All prices include VAT and a receipt will be supplied Thanks for looking Enjoy your visit!
    Payment
    Payment
    We accept payment PayPal for online orders. All Auction and “Buy It Now” prices include VAT.
    We take great care packaging every item to ensure safe shipment to you. We charge a postage fee only to cover our costs of materials and labour. Once your order has been processed and we have received cleared payment, your item will be dispatched as soon as possible. Please allow extra time if you are paying by Echeque.
    Terms
    Terms
    We warrantee and represent that the goods are as described in the above listing. We specifically disclaim any implied warranties of title, merchantability, fitness for a particular purpose and non-infringement. Customers should satisfy themselves that any item choice made is suitable for their intended purpose or use. We pride ourselves on our customer service. In the rare event that you have a problem with your item please contact us and we’ll be happy to help.
    Returns
    Returns
    Genuinely faulty goods will be replaced or money refunded, however we must be advised of any faulty goods upon receipt of the item. It is the customers responsibility to pay for and ship the item back to us. If the item is found to be faulty, we will also refund the postage cost. If you want to return a part that is just not required anymore please go to My eBay and open a returns request , if a part is faulty please also use the eBay return procedure and send to us for testing in both cases making sure you enclose a copy of the original purchase invoice which would have been sent with the item..
    Helpful Links
    Add to Favourite Sellers
    Sign up to Newsletter
    View Feedback
    Contact Seller
    Visit seller’s eBay Shop
    About Seller Page
    More Items!
    View more great items
    LR065340 Land Rover Discovery 3 & 4 Motorhaube-Fang Anti-diebstahl Alarm
    €41,93
    DB1500 Resistente Split Carica 200 Amp Relè Doppio Batteria Carica
    €27,80
    LR065340 Land Rover Range Rover Evoque Capot Prise Antivol Alarme Interrupteur
    €41,93
    LR056138 Land Rover Freelander 2 & Range Rover Evoque Pollen Filtro de Cabina
    €16,65
    Powered by
    Frooition
    Frooition Frooition | No-js Template | eBay design, eBay store design, eBay shop design, eBay template design, eBay listing design (ver:froo_no_js)
    This listing is currently undergoing maintenance, we apologise for any inconvenience caused.
    Brand
    IBS Britpart
    Manufacturer Part Number
    DA1174
    EAN
    Does not apply

    Main Menu